C A M E R A S :
|
Every full camera system
generally includes:
· The specific camera (or cameras) with power supply
· appropriate optical couplers (based on chip size)
· An A-to-D and D-to-A card and Control Panel for electrode recording and TTL outputs for experimental control
· A PC (Up-to-date Workstation); Monitor not included
· Turbo-SM for data acquisition and analysis
|
| | |
FOR LIGHT LEVEL : | DESCRIPTION | CODE |
| | |
Low to High |
DaVinci-2K-CMOS camera - SciMeasure 2048x2048 camera 1024x320 @>2KHz-NDR, 1KHz-CDS; 2048x2048 @>200Hz-NDR, 100Hz-CDS; see All Configurations (NDR mode for STORM imaging and molecule tracking, windowing and on-chip binning for high speed VSD/Ca imaging) | DV2K |
| | |
Low to High |
Dual VSD and Ca Imaging System - Integrating single DaVinci-2K-CMOS camera, Cairn OptoSplit for large sensor, and Macroscope. | DV2K-DF |
| | |
Low to High |
DaVinci-1K-CMOS camera - A skinny version of SciMeasure 2048x2048 camera 512x320 @>2KHz-NDR, 1KHz-CDS; 1024x1024 @>400Hz-NDR, 200Hz-CDS; see All Configurations (NDR mode for STORM imaging and molecule tracking, windowing and on-chip binning for high speed VSD/Ca imaging) | DV1K |
| | |
Low to Medium | FastCMOS-128X camera - SciMeasure 128x128 camera (for high speed tracking) | FCMS-128X |
| | |
Low to Medium |
NeuroCCD-SMQ imaging system - Sensor discontinued | NCS01 |
| | |
Low to Medium | NeuroCCD-SM256 imaging system - SciMeasure 256X256 camera (for VSD, GEVI, Ca imaging) | NCS256 |
| | |
High | NeuroCMOS-DW128 imaging system - SciMeasure Deep Well 128x128 camera (for VSD imaging, iSCAT) | NMS128 |
| | |
High | NeuroCMOS-DW128f imaging system - SciMeasure fast Deep Well camera (for VSD imaging, iSCAT) | NMS128F |
| | |
high | Dual NeuroCMOS-DW128f imaging system - 2 SciMeasure fast DW camera heads with one controller | NMS128F-DH |
| | |
|
O T H E R H A R D W A R E : |
| | |
DESCRIPTION | CODE |
| | |
Macroscope-IIa -· 2X and 4X lenses · Mount for ordinary microscope objective lens · Dichroic mirror | · Beam diverter · Dual C-mount ports · C-mount |
| MA01 |
| | |
Ratio-Add-On -
· 75W Optosource xenon arc lamp and power supply (Ultra high point intensity) · Light source output coupling for Cairn lamphouse (incl.iris Diaphragm) · Optoscan monochromator with full rapid galvo grating and slit width with Power supply · UV transmitting liquid light guide (3mm diameter, 2 metre long) | · Calibration and filter test accessory for Optoscan. · Episcopic light guide coupling for specified microscope. · Additional Microstar A-to-D card |
| NCS-RAO |